How to Install a Radon System with RetroShield Parts
Never installed a radon system before? This page walks the whole job,
start to finish, the way a working mitigator does it — with the RetroShield parts doing
the fussy work for you.
Start here · The RetroShield lineup
Do you need a 3″ vent or a 4″ vent?
Every RetroShield product is below. Pick your vent size first — the fan cover,
message bracket, and gutter bracket are made to match it — then work your way
down the page: gather your parts, then follow the 5-phase install.
Showing the parts for a 3″ vent — match your fan, pipe, and hole saw to this size all the way down.
For 3″ vent
Fan Cover — 3″
Powder-coated steel cover for the radon fan.
Part DS-R7-0001-3.5
For 3″ vent
PVC Message Bracket — 3″
Holds the vent pipe and the system message label.
For 3″ vent
Gutter Bracket — 3″
Supports the vent pipe where the run passes the gutter.
For 4″ vent
Fan Cover — 4″
Powder-coated steel cover for the radon fan.
Part DS-0001-R5-4.5
For 4″ vent
PVC Message Bracket — 4″
Holds the vent pipe and the system message label.
For 4″ vent
Gutter Bracket — 4″
Supports the vent pipe where the run passes the gutter.
Every system — either size
Every system
Sump Lid Cover — Radon
Round sealed lid and frame assembly, 23″ across — the suction point cover for the mitigation system.
Every system
Sump Cover — Pump Only
Same cover family with a pump hole and cord slot, no radon hole — for pump access where radon is handled separately.
Every system
Sump Pump Stand
Steel stand that holds the sump pump at height in the pit.
Radon is a radioactive gas that seeps up from the soil under your home. A radon system
reverses the flow: a fan pulls air — and the radon in it — from beneath the concrete
slab, collects it at the sump pit, and vents it safely outside above the roofline area,
before it can enter the house.
Under the slab→Sump pit→Fan→Vent pipe→Outside air
It runs 24/7. The fan never switches off. It uses about as much power as a light bulb, and it only protects the home while it’s running — that’s why the system includes a manometer, so you can see at a glance that it’s still pulling.
1
Before You Start
Everything on these lists should be on site before the first hole is drilled. Check items off as you stage them.
In the RetroShield boxes
RetroShield part
Sump Pit Cover
A pre-made, sealed cover assembly that fits the sump pit and gives the system an airtight suction point — no site-built sealing job to get wrong.
RetroShield part
Fan Cover
A pre-made cover assembly for the fan: protects it from weather, quiets it, and keeps the exterior run looking clean and finished.
Rest of the system — gather these
Tools
Three decisions before you drill
Test first — know your number.
Run a radon test before you install. It tells you a system is needed, and it’s the baseline your after-install retest gets compared against.
Pick the fan spot.
Outside, on a straight vertical run of pipe, away from windows and doors so vented air can’t drift back in. A straight run pulls better and looks better.
Check your local rules.
Some states and towns require a licensed mitigator or a permit for radon work, and electrical work has its own rules. Check before you start, not after.
2
The Install — 5 Phases
Work the phases in order. Each one sets up the next, and the system doesn’t get switched on until Phase 4.
1
Phase 1
Prep & Access
Find the route out of the house, and prove it’s clear before cutting the full-size hole.
Walk the job and talk it through.
Walk around inside and out. Confirm the sump pit location, the fan spot you picked, and the path the pipe will take between them.
Drill the pilot hole from inside.
From the basement, drill the long pilot bit through the rim joist at the exact center of where the pipe will exit. This small hole marks your spot on the outside wall.
Check the outside clearance.
Go outside and look at where the pilot hole landed. Check for gutters, siding trim, utilities, and anything else in the way of the full-size hole and the vertical run.
Drill the full hole from outside.
Using the pilot hole as your center, cut the full opening from the outside in: a 3.5″ OD hole for a 3″ vent system, or a 4.5″ OD hole for a 4″ vent system. Working from outside keeps the finished edge clean where it will be seen.
2
Phase 2
Pipe & Sump
Build the inside run: from the hole, down to the sump pit, sealed and secure.
Feed the vertical pipe through the hole.
From outside, push the vertical pipe through the rim joist opening into the basement.
Fit the first elbow inside, and secure the pipe.
Attach the first elbow inside to turn the run downward, then secure the pipe to the wall or joists so the run is rigid and can’t shift or stress the joints. The RetroShield PVC Message Brackets work well for this — and the same brackets also work for securing the pipe outside, to the house wall.
Build the vertical run with elbows.
Work down and across with elbows, staying inside, until the run reaches the sump pit. Dry-fit as you go; glue once the route is right.
Mount the sump cover and discharge line.
Set the cover assembly on the pit and connect the discharge line from the cover to your pipe run, sealed airtight.
Wire the inside electrical.
Run the inside wiring for the fan, including the fan switch, using the wire nuts and cable grips. Follow your local electrical code.
RetroShieldThe Sump Pit Cover goes on in this phase. It arrives as a pre-made sealed assembly — seat it on the pit, connect the discharge line, and the suction point is done. An unsealed pit is the #1 reason home-built systems underperform.
3
Phase 3
Fan Cover & Finish
Finish the outside run: fan covered, pipe straight, every joint sealed.
Cut the excess pipe.
Trim the outside pipe to final length with the Sawsall so the fan and cover sit at the right height on the run.
Mount the fan cover and final pipe.
Install the fan with its Fernco couplers, fit the pre-made Fan Cover assembly, and set the final pipe so the whole exterior run routes in one clean vertical line.
Final glue on the outside joints.
Prime and cement every outside joint with the outside glue set. A radon system is only as good as its seals — a leaking joint vents radon right back at the house.
Seal every penetration with caulk.
Caulk around the rim joist hole and every other penetration, inside and out, until the system is airtight end to end.
Route and secure the power cord.
Run the fan’s power cord neatly to its source and secure it so it can’t sag, chafe, or get snagged.
RetroShieldThe Fan Cover goes on in this phase as a pre-made assembly — fan protected from the weather, noise knocked down, and no exposed fan and wiring for the neighborhood to look at. In this system the Fan Cover does two things: it protects the fan, and it also acts as a giant bracket to hold the fan assembly in place. It is secured to the house with only four screws (not included).
4
Phase 4
Test
Switch it on and prove it works — with your ears, your eyes, and the gauge.
Turn the fan on and check every joint for leaks.
Walk the entire run, inside and out. Listen and feel at every joint, coupler, and the pit cover. Any leak gets sealed now, while the tools are still out.
Read the U-tube manometer.
The two liquid columns should sit uneven — that difference is the vacuum the fan is pulling, measured in inches of water column (in. WC). What the number tells you:
≈ 1.0 in. WC
Good communication
The ground under the slab is talking to the pit — usually gravel fill. Air moves freely, the fan is pulling easily, and one suction point will do the job.
≈ 2.5 in. WC
Tight soil — fan working hard
Tight clay or mud under the slab barely lets air move, so vacuum climbs and the fan strains. Older fieldstone and clay-soil houses may need a second suction point — that’s a pro-level call (see below).
Retest the home’s radon.
After the system has run, test the home again and compare against your before number. The retest is the only proof the job is done.
5
Phase 5
Cleanup
Leave the home cleaner than you found it, and leave the proof of the job behind.
Remove everything you brought in.
Tools, scrap PVC, cut-offs, and trash all go out. Sweep the work areas inside and out.
Label the system.
Label the system at the pipe and manometer so anyone in the home knows what it is, that it must stay running, and how to tell it’s working.
Leave the paperwork.
Leave the homeowner a record of the job: the parts installed, the fan model, and the manometer reading from test day. If a fan ever gets replaced years from now, that sheet is where the next person starts.
3
When to Call a Pro
A standard sump-pit basement is a fair DIY job. These situations are not — they change the design of the system, not just the effort.
No sump pit, or a mixed foundation. Slab plus crawl space, or part basement and part slab — each section pulls differently and the system has to be designed for it.
Stone or rubble foundations. Old fieldstone walls leak air everywhere; sealing and suction design on these is specialist work.
The manometer stays very high. Readings up near 2.5 in. WC that don’t settle mean tight soil the fan can’t overcome from one pit — a second suction point may be needed.
Electrical beyond your permit or comfort. If the fan circuit means panel work or anything you’re unsure of, that part belongs to an electrician.
Your state requires a licensed mitigator. Some states license radon mitigation. If yours does, the install has to be done — or at least signed off — by a license holder.
4
Watch It Done
Prefer to watch the job before you start it?
Install Video — Coming Soon
We’re filming a full RetroShield install, phase by phase, on a real job. When it’s ready, it will play right here — the same QR code on your box will bring you to it.